RPM | Model dependent, see model specifications below* |
MOUNTING | End of shaft with threaded stud or flange, or with set screws onto shaft (through-hole ERGT Series) Click here for installation and best practices video. |
HOUSING | 304 Stainless Steel |
OPERATION | Can be operated in any direction or orientation |
MAINTENANCE | Features permanently lubricated bearings, brush-free design requires no user maintenance |
ERG-10000 Model Specifications
AMPERAGE | Model dependent, see specifications chart - 100% overload allowed for <60 seconds |
FREQUENCY | DC to 1GHz - Contact Meridian Laboratory for ampacity ratings at higher frequencies |
STATIONARY CONTACT RESISTANCE | <0.01mΩ |
ROTATING CONTACT RESISTANCE | Same as stationary contact resistance (<0.1mΩ) |
ELECTRICAL NOISE | <0.01uV |
OPERATION | Intrinsically immune to internal arcing |
ERG-10000 Model Specifications